TE805 Controller

 

TE805 Controller

 

TE805 board allows manual and automatic control on Generating Sets. It consists of: ABS frontal part with polycarbonate panel for installation by back part of the panel. It assure an IP54 protection.

 

ELECTRICAL MEASURES VISUALIZATION

  • Generator and mains voltage phases on L1-L2-L3
  • Generator and mains frequency
  • Genarator rev-counter
  • Ampere for every phase of Generator and Mains on L1- L2-L3
  • kVA
  • battery volt
  • Hourcounter
  • hours to the maintenance

 

There are some special functions that can be activated by entering a password in a special program menu called SET-Up. The functions are:

 

  • Start/Stop genset on mains threshold kW

It allows setting up the minimal and maximum threshold of the kW when it wants to start or stop the generator with load switching from mains to genset

  • Dummy load command

It allows inserting a fictitious load in order to avoid the generator on with low load. Its possible to set up the minimal and maximum threshold in kW of intervention with relative times and cycles.

  • Rent hours

It allows to set up an overdue time for rent which stops the generators.

  • Block for Automatic and Test

It can be used when it is necessary to use generator only in Manual mode .This function allows Automatic and Test functions turn off.

  • Engine Starter for TLGR failure

In case the generator finds breakdown on mains contactor, the genset is automatically started and load is transferred under the genset contactor

  • Exit from functioning mode

It is possible to activate an exit for indication for board functioning status

  • Remote start

This function is on only on automatic functioning. it allows start and stop the generator by external contact opening and closing even if mains is on. Switching occurs only when lack of mains is surveyed.

  • SCR

This function is on only during automatic functioning and it allows:

* To start the generator through the closing of an external contact

* To carry out the load switching on the generator when mains is on

* To stop the generator when contactor opens and to switch the load to the mains

  • EJP

It is a specific function for French market and it can be activated in two different ways:

EJP (standard) by closing an outside contact, then, after an adjustable time of 30', the generator will start.

The closing of a second contact controls the load switching to the generator EJP/T- starter of the generator happens by closing an outside contact; the switching comes after an adjustable time of max 30'

 

Note

In both case it is possible to select whether the load shall remain on the generator or if it has to be switched on the mains in case of generator failure,

 